Home Power Inverter

The Wirentech 10kW hybrid inverter delivers 120/240V split-phase output on a 51.2V battery platform for larger household loads, solar self-use, and planned backup power.

Large Load Planning

Plan compatible large-home circuits such as central HVAC, well pumps, cooking equipment, and scheduled EV charging while keeping total output within 10kW and single-phase loading within 7.2kW.

Solar Class Selection

Select the exact model suffix before array design: the M220 PV class supports 6kW plus 6kW, while the M250 class supports 9kW plus 9kW; both use a 90–450V MPPT range and 500V maximum VOC.

Multiple Energy Sources

Coordinate solar, grid, generator, and 51.2V battery energy to support solar self-use, scheduled charging, backup reserve, and multiple recovery paths for a 120/240V split-phase system.

Output Surge Performance

The inverter provides 10kW continuous output, 15kVA peak power, 10ms typical transfer, motor-starting capability up to 5HP, a 7.2kW single-phase limit, and greater than 92% listed maximum efficiency.

Battery Platform Matching

Match a capable 51.2V battery bank to the documented 40–58.6Vdc operating range and 44V minimum start voltage, with 120A maximum AC charging, 220A or 250A maximum PV charging by suffix, and USB plus RS485 communication.

Integrated Electrical Protection

Manual-documented safeguards address overload, short circuit, PV reverse polarity, AC reverse conditions, overvoltage, and temperature while still requiring correctly sized external protection, wiring, grounding, and installation.

Parallel Model Requirements

Parallel operation is limited to the documented -500P suffix for configurations of up to six units; the base version must not be assumed to support parallel operation.

Professional Installation Planning

The inverter measures 620 × 450 × 132 mm, weighs 23.5 kg or 51.8 lb, operates from -10°C to 55°C, and requires suitable wall support, airflow, conductor sizing, circuit protection, and professional commissioning.

FAQs

What is included with the inverter?

This product describes one Wirentech 10kW 120/240V split-phase hybrid inverter. Batteries, solar panels, generator equipment, breakers, disconnects, cables, and other system components are not included unless the exact product listing states otherwise. Confirm the full model suffix and included accessories before ordering.

Can it support both 120V and 240V loads?

Yes. The inverter provides 120/240V split-phase output for compatible circuits. Total continuous output is 10kW, while loading assigned to a single phase is limited to 7.2kW. Stagger high-demand equipment and plan phase balance, simultaneous demand, and starting current with a qualified installer.

How much continuous and peak power does it provide?

The inverter provides 10kW of continuous output and up to 15kVA of peak power, with 10ms typical transfer and motor-starting capability up to 5HP under the specified conditions. Verify the running watts and starting surge of every connected appliance or motor instead of sizing from rated output alone.

What solar input does each model support?

PV input depends on the exact suffix. The M220 PV class is documented for 6kW plus 6kW, or 12kW total, while the M250 class is documented for 9kW plus 9kW, or 18kW total. Both list a 90–450V MPPT range and 500V maximum open-circuit voltage. These are electrical limits, not promised energy production or recharge times.

Can it use solar, grid, generator, and battery power?

Yes. The hybrid platform can coordinate solar input, grid charging, generator charging, and battery storage for solar self-use, scheduled charging, outage reserve, and more than one recovery path. Final source configuration, transfer logic, and charging settings must follow the exact inverter manual and applicable electrical codes.

Which battery platform should be used?

The inverter is designed around a 51.2V nominal battery platform with a documented 40–58.6Vdc operating range and 44V minimum start voltage. The listed maximum AC charging current is 120A, while maximum PV charging is 220A or 250A depending on the suffix. Confirm battery current capability, BMS protocol, and charging settings before connection. USB and RS485 communication are supported.

What protection functions does the inverter provide?

Manual-documented safeguards address overload, short circuit, PV reverse polarity, AC reverse conditions, overvoltage, and temperature. These internal functions do not replace correctly sized breakers, fuses, disconnects, conductors, grounding, ventilation, or professional installation.

Can multiple 10kW inverters operate in parallel?

Parallel operation applies only to the documented -500P suffix, with configurations of up to six units. Do not assume that a base model supports parallel operation. Verify the complete model number, parallel accessories, communication requirements, and installation instructions before ordering or commissioning.

What should I verify before installation?

Verify the split-phase circuit plan, phase balance, battery capability, PV class, generator configuration, model suffix, conductor sizes, protection devices, airflow, and wall support. The inverter measures 620 × 450 × 132 mm, weighs 23.5 kg or 51.8 lb, and has a listed operating range of -10°C to 55°C. A 5-year limited inverter warranty applies under its terms.