High Output Inverter

The 6.5kW hybrid inverter provides 120V single-phase pure sine wave output with additional headroom for selected household and workshop loads on a 48V battery platform.

Off Grid Applications

Support compatible cabin essentials, well and water equipment, mini-split cooling, and workshop loads while scheduling high-demand equipment and keeping single-phase loading within 6kW.

Dual MPPT Solar

Two 4.5kW MPPT groups provide up to 9kW of documented PV input with a 90–450V tracking range, 500V maximum VOC, 120A maximum AC charging, and 150A maximum PV charging.

Multiple Energy Sources

Solar, grid, generator, and battery inputs provide multiple energy and recovery paths for an off-grid 120/240V split-phase system with 7.2kW continuous output.

Output Surge Performance

The inverter provides 7.2kW continuous output, 10.8kVA peak power, 10ms typical transfer, motor-starting capability up to 4HP, and greater than 93% listed maximum inverter efficiency.

Battery Platform Matching

The inverter is designed around a 51.2V battery bank with a documented 40–58.6Vdc operating range, 44V minimum start voltage, and USB plus RS485 communication support.

Integrated Electrical Protection

Manual-documented safeguards address overload, short circuit, PV reverse polarity, AC reverse conditions, overvoltage, and temperature while still requiring correct external protection and installation.

Parallel Model Requirements

Parallel operation is limited to the documented GES4872M150-500P version for configurations of up to six units; the base version must not be assumed to support parallel operation.

Professional Installation Planning

The inverter measures 580 × 359 × 127 mm, weighs 15.9 kg or 35.1 lb, operates from -10°C to 55°C, and requires suitable wall support, airflow, wiring, phase balancing, and professional commissioning.

FAQs

What is included with the inverter?

This product describes one Wirentech 7.2kW 120/240V split-phase hybrid inverter. Batteries, solar panels, generator equipment, breakers, disconnects, cables, and other system components are not included unless the exact product listing states otherwise. Confirm the model suffix and included accessories before ordering.

Can it support both 120V and 240V loads?

Yes. The inverter provides 120/240V split-phase output for compatible circuits. The total continuous output is 7.2kW, while loading assigned to a single phase is limited to 6kW. Plan phase balance, simultaneous demand, and motor starting current with a qualified installer.

How much continuous and peak power does it provide?

The inverter provides 7.2kW of continuous output and up to 10.8kVA of peak power, with 10ms typical transfer and motor-starting capability up to 4HP under the specified conditions. Verify running watts and starting surge separately for every connected appliance or motor.

What solar input does the inverter support?

Two MPPT groups accept up to 4.5kW each, providing up to 9kW of documented PV input. The listed operating window is 90–450V MPPT with a 500V maximum PV open-circuit voltage. These are electrical limits, not a promised battery recharge time.

Can it use solar, grid, generator, and battery power?

Yes. The hybrid platform supports solar input, grid charging, generator charging, and battery storage, giving an off-grid system more than one recovery path. Final source configuration, transfer logic, and charging settings must follow the inverter manual and applicable electrical codes.

Which battery platform should be used?

The inverter is designed around a 51.2V nominal battery platform with a documented 40–58.6Vdc operating range and a 44V minimum start voltage. The listed charging limits are 120A from AC and 150A from PV. Confirm battery voltage, current limits, BMS protocol, and charge settings before connection. USB and RS485 communication are supported.

What protection functions does the inverter provide?

Manual-documented safeguards address overload, short circuit, PV reverse polarity, AC reverse conditions, overvoltage, and temperature. These internal features do not replace correctly sized breakers, fuses, disconnects, wiring, grounding, ventilation, or professional installation.

Can multiple 7.2kW inverters operate in parallel?

Parallel support applies only to the documented GES4872M150-500P model, with configurations of up to six units. Do not assume that the base version supports parallel operation; verify the complete model suffix before ordering and commissioning.

What should I verify before installation?

Verify the split-phase circuit plan, 51.2V battery compatibility, PV design, generator configuration, model suffix, conductor sizes, breaker ratings, airflow, and wall support. The inverter measures 580 × 359 × 127 mm, weighs 15.9 kg or 35.1 lb, and has a listed operating range of -10°C to 55°C. A 5-year limited inverter warranty applies under its terms.